A NOVEL EOR POLYMER (Ⅰ)—STUDY ON GELATION OF RESORCINOL-FORMALDEHYDE SYSTEMS
Papers|Updated:2021-06-21
|
A NOVEL EOR POLYMER (Ⅰ)—STUDY ON GELATION OF RESORCINOL-FORMALDEHYDE SYSTEMS
A NOVEL EOR POLYMER (Ⅰ)—STUDY ON GELATION OF RESORCINOL-FORMALDEHYDE SYSTEMS
高分子科学(英文版)1995年13卷第1期 页码:59-65
Affiliations:
1. Department of Material Engineering
2. Zhengzhou University
3. Zhengzhou 450052
4. China
5. The Tertiary Oil Recovery Project
6. The University of Kansas
7. Lawrence
8. KS 66045
9. U. S. A.
Author bio:
Funds:
DOI:
中图分类号:O631
纸质出版:1995-03-20
Accepted:
Scan QR Code
[1]庄银凤,Stanley McCool,G.Paul Willhite,Don W.Green.A NOVEL EOR POLYMER (Ⅰ)—STUDY ON GELATION OF RESORCINOL-FORMALDEHYDE SYSTEMS[J].Chinese Journal of Polymer Science,1995,{4}(01):59-65.
ZHUANG Yinfeng, Stanley McCool, G.Paul Willhite, et al. A NOVEL EOR POLYMER (Ⅰ)—STUDY ON GELATION OF RESORCINOL-FORMALDEHYDE SYSTEMS[J]. 1995, 13(1): 59-65.
[1]庄银凤,Stanley McCool,G.Paul Willhite,Don W.Green.A NOVEL EOR POLYMER (Ⅰ)—STUDY ON GELATION OF RESORCINOL-FORMALDEHYDE SYSTEMS[J].Chinese Journal of Polymer Science,1995,{4}(01):59-65.DOI:
ZHUANG Yinfeng, Stanley McCool, G.Paul Willhite, et al. A NOVEL EOR POLYMER (Ⅰ)—STUDY ON GELATION OF RESORCINOL-FORMALDEHYDE SYSTEMS[J]. 1995, 13(1): 59-65.DOI:
A NOVEL EOR POLYMER (Ⅰ)—STUDY ON GELATION OF RESORCINOL-FORMALDEHYDE SYSTEMS
<正> Factors affecting the gelation of resorcinol-formaldehyde systems have been examined overvariable ranges applicable to oilfield use. Gelation of resorcinol-formaldehyde (RF) system wassensitive to pH
salinity and hardness. Generally
this gel system could be used in fresh water orlow salinity brine at pH higher than about 9. The application would require careful monitoring ofinjection fluids to avoid premature gelation or prolonged shut-in times
especially under conditionsof low salinity and high pH. Salinity and hardness compatibilities of the system were improved bysulfomethylation of resorcinol. Aqueous sulfomethylated resorcinol formaldehyde (SMRF)system could be used in brine with higher salinity and hardness and at a wider pH range of 5--10.
Abstract
Factors affecting the gelation of resorcinol-formaldehyde systems have been examined overvariable ranges applicable to oilfield use. Gelation of resorcinol-formaldehyde (RF) system wassensitive to pH
salinity and hardness. Generally
this gel system could be used in fresh water orlow salinity brine at pH higher than about 9. The application would require careful monitoring ofinjection fluids to avoid premature gelation or prolonged shut-in times
especially under conditionsof low salinity and high pH. Salinity and hardness compatibilities of the system were improved bysulfomethylation of resorcinol. Aqueous sulfomethylated resorcinol formaldehyde (SMRF)system could be used in brine with higher salinity and hardness and at a wider pH range of 5--10.
关键词
Keywords
references