A NEW METHOD FOR ESTIMATION OF WEIGHT-AVERAGE MOLECULAR WEIGHT OF POLYMER FROM THE INTRINSIC VISCOSITY AND CHROMATOGRAM
Papers|Updated:2021-06-21
|
A NEW METHOD FOR ESTIMATION OF WEIGHT-AVERAGE MOLECULAR WEIGHT OF POLYMER FROM THE INTRINSIC VISCOSITY AND CHROMATOGRAM
A NEW METHOD FOR ESTIMATION OF WEIGHT-AVERAGE MOLECULAR WEIGHT OF POLYMER FROM THE INTRINSIC VISCOSITY AND CHROMATOGRAM
高分子科学(英文版)1986年4卷第2期 页码:142-147
Affiliations:
Author bio:
Funds:
DOI:
中图分类号:
纸质出版:1986-06-20
Accepted:
Scan QR Code
ZHANG Zhaomu, YANG Guojun. A NEW METHOD FOR ESTIMATION OF WEIGHT-AVERAGE MOLECULAR WEIGHT OF POLYMER FROM THE INTRINSIC VISCOSITY AND CHROMATOGRAM[J]. 高分子科学(英文版), 1986,4(2):142-147.
ZHANG Zhaomu, YANG Guojun. A NEW METHOD FOR ESTIMATION OF WEIGHT-AVERAGE MOLECULAR WEIGHT OF POLYMER FROM THE INTRINSIC VISCOSITY AND CHROMATOGRAM[J]. 1986, 4(2): 142-147.
ZHANG Zhaomu, YANG Guojun. A NEW METHOD FOR ESTIMATION OF WEIGHT-AVERAGE MOLECULAR WEIGHT OF POLYMER FROM THE INTRINSIC VISCOSITY AND CHROMATOGRAM[J]. 高分子科学(英文版), 1986,4(2):142-147.DOI:
ZHANG Zhaomu, YANG Guojun. A NEW METHOD FOR ESTIMATION OF WEIGHT-AVERAGE MOLECULAR WEIGHT OF POLYMER FROM THE INTRINSIC VISCOSITY AND CHROMATOGRAM[J]. 1986, 4(2): 142-147.DOI:
A NEW METHOD FOR ESTIMATION OF WEIGHT-AVERAGE MOLECULAR WEIGHT OF POLYMER FROM THE INTRINSIC VISCOSITY AND CHROMATOGRAM
A new method is proposed for estimation of weight-average molecular weight from the intrinsicviscosity and GPC chromatogram of a polymer sample for which Mark-Houwink coefficients are notknown. The method bases on an approximate relationship between GPC data and the intrinsicviscosity of the sample. Reliability of this method was tested by comparing with the universalcalibration method which requires known Mark-Houwink coefficients for seven samples havingdifferent molecular weight distributions. Results obtained by the new method are in excellent agree ment with those by the universal calibration method.
Abstract
A new method is proposed for estimation of weight-average molecular weight from the intrinsicviscosity and GPC chromatogram of a polymer sample for which Mark-Houwink coefficients are notknown. The method bases on an approximate relationship between GPC data and the intrinsicviscosity of the sample. Reliability of this method was tested by comparing with the universalcalibration method which requires known Mark-Houwink coefficients for seven samples havingdifferent molecular weight distributions. Results obtained by the new method are in excellent agree ment with those by the universal calibration method.
关键词
Keywords
references
The trial reading is over, you can activate your VIP account to continue reading.