SIMULTANEOUS CALIBRATION OF MOLECULAR WEIGHT SEPARATION AND COLUMN DISPERSION OF SEC WITH CHARACTERIZED POLYMER STANDARDS
Papers|Updated:2021-06-21
|
SIMULTANEOUS CALIBRATION OF MOLECULAR WEIGHT SEPARATION AND COLUMN DISPERSION OF SEC WITH CHARACTERIZED POLYMER STANDARDS
SIMULTANEOUS CALIBRATION OF MOLECULAR WEIGHT SEPARATION AND COLUMN DISPERSION OF SEC WITH CHARACTERIZED POLYMER STANDARDS
高分子科学(英文版)1983年1卷第2期 页码:125-131
Affiliations:
Author bio:
Funds:
DOI:
中图分类号:
纸质出版:1983-11-20
Accepted:
Scan QR Code
CHENG Rongshi, BO Shuqin. SIMULTANEOUS CALIBRATION OF MOLECULAR WEIGHT SEPARATION AND COLUMN DISPERSION OF SEC WITH CHARACTERIZED POLYMER STANDARDS[J]. 高分子科学(英文版), 1983,1(2):125-131.
CHENG Rongshi, BO Shuqin. SIMULTANEOUS CALIBRATION OF MOLECULAR WEIGHT SEPARATION AND COLUMN DISPERSION OF SEC WITH CHARACTERIZED POLYMER STANDARDS[J]. 1983, 1(2): 125-131.
CHENG Rongshi, BO Shuqin. SIMULTANEOUS CALIBRATION OF MOLECULAR WEIGHT SEPARATION AND COLUMN DISPERSION OF SEC WITH CHARACTERIZED POLYMER STANDARDS[J]. 高分子科学(英文版), 1983,1(2):125-131.DOI:
CHENG Rongshi, BO Shuqin. SIMULTANEOUS CALIBRATION OF MOLECULAR WEIGHT SEPARATION AND COLUMN DISPERSION OF SEC WITH CHARACTERIZED POLYMER STANDARDS[J]. 1983, 1(2): 125-131.DOI:
SIMULTANEOUS CALIBRATION OF MOLECULAR WEIGHT SEPARATION AND COLUMN DISPERSION OF SEC WITH CHARACTERIZED POLYMER STANDARDS
With the aid of the theoretical relationship between the calibration relation of a SEC column for the monodisperse polymer species under ideal working condition and the effective relations between the molecular weight and the elution volume for characterized polymer samples
a computational procedure for simultaneous calibration of molecular weight separation and column dispersion is proposed. From the experimental chromatograms of narrow MWD polystyrene standards and broad MWD 1
2-polybutadiene fractions the spreading factor with the elution volume is independent upon the polymer sample used.
Abstract
With the aid of the theoretical relationship between the calibration relation of a SEC column for the monodisperse polymer species under ideal working condition and the effective relations between the molecular weight and the elution volume for characterized polymer samples
a computational procedure for simultaneous calibration of molecular weight separation and column dispersion is proposed. From the experimental chromatograms of narrow MWD polystyrene standards and broad MWD 1
2-polybutadiene fractions the spreading factor with the elution volume is independent upon the polymer sample used.
关键词
Keywords
references
The trial reading is over, you can activate your VIP account to continue reading.