Flame-retardant Wrapped Ramie Fibers towards Suppressing "Candlewick Effect" of Polypropylene/Ramie Fiber Composites
PAPER|Updated:2021-06-21
|
Flame-retardant Wrapped Ramie Fibers towards Suppressing "Candlewick Effect" of Polypropylene/Ramie Fiber Composites
Chinese Journal of Polymer ScienceVol. 33, Issue 1, Pages: 84-94(2015)
Affiliations:
Center for Degradable and Flame-Retardant Polymeric Materials, College of Chemistry, State Key Laboratory of Polymer Materials Engineering, National Engineering Laboratory of Eco-Friendly Polymeric Materials (Sichuan), Analytical and Testing Center, Sichuan University, Chengdu 610064, China
Shuang-lan Du, Xue-bao Lin, Rong-kun Jian, et al. Flame-retardant Wrapped Ramie Fibers towards Suppressing "Candlewick Effect" of Polypropylene/Ramie Fiber Composites[J]. Chinese Journal of Polymer Science, 2015, 33(1): 84-94.
DOI:
Shuang-lan Du, Xue-bao Lin, Rong-kun Jian, et al. Flame-retardant Wrapped Ramie Fibers towards Suppressing "Candlewick Effect" of Polypropylene/Ramie Fiber Composites[J]. Chinese Journal of Polymer Science, 2015, 33(1): 84-94.DOI: 10.1007/s10118-015-1560-z.
Flame-retardant Wrapped Ramie Fibers towards Suppressing "Candlewick Effect" of Polypropylene/Ramie Fiber Composites
a flame-retardant polypropylene (PP)/ramie fiber (RF) composite was prepared. The ramie fibers were wrapped chemically by a phosphorus- and nitrogen-containing flame retardant (FR) produced
via in situ
condensation reaction so as to suppress their candlewick effect. Fourier transform infrared spectroscopy (FTIR)
X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM) demonstrated that the ramie fibers wrapped chemically by FR (FR-RF) were obtained successfully. Thermogravimatric test showed that the PP/FR-RF composite had more residue and better thermal stability at high temperatures than the PP/RF composite. Cone calorimeter (CC) results indicated that the peak of heat release rate (PHRR) and total heat release (THR) correspondingly decreased by 23.4% and 12.5% compared with the values of neat PP/RF. The PP/FR-RF composite created a continuous and compact char layer after the combustion. Combining FTIR analysis of char residue after CC test with heat conduction coefficient results
it could be concluded that the charring of FR on RF greatly weakened the candlewick effect of RF
and more char residue in the RF domain facilitated the formation of more continuous and compact char layer in the whole combustion zone
consequently protected PP composites during combustion
resulting in the better flame retardancy of PP/FR-RF composite than that of PP/RF composite.
关键词
Keywords
references
The trial reading is over, you can activate your VIP account to continue reading.