In Vivo Degradation Behavior of Porous Composite Scaffolds of Poly(lactide-co-glycolide) and Nano-hydroxyapatite Surface Grafted with Poly(L-lactide)
Chinese Journal of Polymer ScienceVol. 32, Issue 6, Pages: 805-816(2014)
Affiliations:
First Hospital, Jilin University, Changchun 130021, China
Key Laboratory of Polymer Ecobiomaterials, Changchun Institute of Applied Chemistry, Graduate School of Chinese Academy of Sciences, Chinese Academy of Sciences, Changchun 130022, China
Author bio:
**Jian-guo Liu (刘建国), E-mail: jgliu.2005@yahoo.com.cn
Yu-feng Tang, Jian-guo Liu, Zong-liang Wang, et al. In Vivo Degradation Behavior of Porous Composite Scaffolds of Poly(lactide-co-glycolide) and Nano-hydroxyapatite Surface Grafted with Poly(L-lactide)[J]. Chinese Journal of Polymer Science, 2014, 32(6): 805-816. DOI: 10.1007/s10118-014-1454-5.
DOI:
Yu-feng Tang, Jian-guo Liu, Zong-liang Wang, et al. In Vivo Degradation Behavior of Porous Composite Scaffolds of Poly(lactide-co-glycolide) and Nano-hydroxyapatite Surface Grafted with Poly(L-lactide)[J]. Chinese Journal of Polymer Science, 2014, 32(6): 805-816. DOI: 10.1007/s10118-014-1454-5.DOI:
In Vivo Degradation Behavior of Porous Composite Scaffolds of Poly(lactide-co-glycolide) and Nano-hydroxyapatite Surface Grafted with Poly(L-lactide)
-glycolide) (PLGA) and hydroxyapatite nanoparticles (n-HAP) surface-grafted with poly(L-lactide) (PLLA) (g-HAP) (g-HAP/PLGA)
was fabricated using the solvent casting/particulate leaching method
and its
in vivo
degradation behavior was investigated by the intramuscular implantation in rabbits. The composite of un-grafted n-HAP/PLGA and neat PLGA were used as controls. The scaffolds had interconnected pore structures with average pore sizes between 137 μm and 148 μm and porosities between 83% and 86%. There was no significant difference in the pore size and porosity among the three scaffolds. Compared with n-HAP/PLGA
the thermo-degradation temperature (
T
c
) of g-HAP/PLGA decreased while its glass transition temperature (
T
g
) increased. The weight change
grey value analysis of radiographs and SEM observation showed that the composite scaffolds of g-HAP/PLGA and n-HAP/PLGA showed slower degradation and higher mineralization than the pure PLGA scaffold after the intramuscular implantation. The rapid degradation of PLGA
g-HAP/PLGA and n-HAP/PLGA occurred at 8–12 weeks
12–16 weeks and 16–20 weeks
respectively. Compared with n-HAP/PLGA
g-HAP/PLGA showed an improved absorption and biomineralization property mostly because of its improved distribution of HAP nanoparticles. The levels of both calcium and phosphorous in serum and urine could be affected to some extent at 3–4 weeks after the implantation of g-HAP/PLGA
but the biochemical detection of serum AST
ALT
ALP
and GGT as well as BUN and CRE showed no obvious influence on the functions of liver and kidney.